Plug-in socket versus fused spur for electric fires
A 2 kW electric fireplace draws 8.7 A at 230 V, comfortably inside a 13 A circuit. Freestanding units can use a standard switched socket, while built-in media walls should wire via an accessible 13 A switched fused spur.
How 2 kW fires connect safely under Irish electrical rules (IS 10101), accessible isolation switches and when a Safe Electric certificate is required.
Free, no obligation. One local installer prices it, not five.
- 2 kWmaximum domestic heater load
- 8.7 Acurrent draw at 230 V
- 13 Astandard socket or spur fuse
- IS 10101Irish wiring standard

13 A plug versus hard-wired switched fused spur
13 A switched wall socket
- Typical use
- Electric stoves, wall-hung fires & flat-wall suites
- Isolation access
- Unplug or flick the adjacent wall switch
- Visual finish
- Visible flex unless tucked behind suite leg
- Typical electrician cost
- €0 if sound socket already sits nearby
13 A switched fused spur (FCU)
- Typical use
- Built-in 3-sided media walls & flush inset fires
- Isolation access
- Dedicated switched faceplate beside or in an alcove
- Visual finish
- 100% hidden power cord inside the stud frame
- Typical electrician cost
- €200 to €500 incl. TV & LED feeds
Never bury a plugged-in 13 A socket permanently inside sealed plasterboard with no external switch. If the fire trips an internal thermal cutout or needs servicing five years later, you must be able to isolate mains power cleanly from outside the wall.
Price my electric fireplace
Four quick taps and our price shows before we ask for a phone number. One local installer rings you, not five.
A wall-hung electric fire, 1200 to 1500 mm wide, fire supplied and fitted: €750 to €1,650, supplied and fitted.
How the price is worked out
The range reflects going Irish supply-and-fit prices for that fire style, width and wall work. Fire-only fitted figures cover the unit, wall or recess installation and connection to an accessible local socket or spur. Full media-wall figures include timber or metal stud framing, plasterboarding, skim plastering and hidden TV cabling. Replacing an old fire allows for RGI gas disconnection or chimney sweeping, vented roof capping and sealing the opening. Custom side cabinetry, acoustic wood slats, quartz hearths and new distribution-board circuits are quoted after measuring your room. Ask whether VAT applies at 13.5% or 23% under Revenue rules. Only an installer who inspects the wall gives a firm quote.
Safe Electric Ireland: Minor Works versus Restricted Works
- Spurring off an existing socket circuit (Minor Works). Extending a sound existing 20 A radial or 32 A ring socket circuit to add a 13 A fused spur and TV outlet falls under Minor Electrical Works in Ireland, though all wiring must still meet IS 10101.
- New circuit from the fuse board (Restricted Works). Under S.I. No. 264 of 2013, adding a new MCB/RCBO or pulling a fresh dedicated cable from the consumer unit is Restricted Electrical Works and must be completed and certified by a Safe Electric Registered Electrical Contractor (REC).
- Never feed a 2 kW fire from a lighting circuit. Lighting circuits carry 6 A or 10 A breakers designed only for lamps, not an 8.7 A space heater.
- Separate media-wall LED strip drivers cleanly. Place low-voltage LED transformers inside a ventilated alcove cupboard or removable access hatch so a dead power brick never requires cutting plaster.
Related fireplace guides
Media wall framing & TV gapTimber vs metal studs, depth allowances and TV heat clearance.
Irish kWh running costsCent-per-hour figures for flame-only, 1 kW and 2 kW heat.
Wall-mounted firesSlim hang-on-the-wall units for flat walls and apartments.
Media wall fireplacesTurnkey stud-built walls, TV recesses, alcove presses and slats.
Replacing open or gas firesRGI disconnection, chimney capping and breast preparation.
Fitting times & scheduleLead times and on-site days from plug-in units to skimmed walls.Common questions before you order
Does an electric fireplace need its own dedicated fuse-board circuit?
Usually no. At 2 kW (8.7 A), a single electric fire runs safely off an existing modern living-room socket circuit via a 13 A switched socket or fused spur, provided the circuit is not already overloaded with other heavy heaters.
Where should the isolation switch go on a media wall?
Fit a discreet switched 13 A fused connection unit on the lower side return of the chimney breast or inside an adjacent alcove cupboard where you can flick it off easily.
Can I run an electric fire on an extension lead?
No. Avoid multi-gang extension leads for 2 kW fan heaters; plug straight into a fixed wall socket or hard-wire to a switched 13 A fused spur.
How much does an electrician charge to wire a media wall in Ireland?
Allow €200 to €500 for a fused fire spur, recessed TV double socket, HDMI brush plates and LED strip feed tapped off a nearby sitting-room circuit.
All electric fireplace pages and guides